Bidspirit auction | GENERAL ELECTRIC OEC FLUOROSTAR BRIGHTNESS


GENERAL ELECTRIC OEC FLUOROSTAR BRIGHTNESS AMPLIFIER - Composed of : • A rolling module (Fluorostar MC) with 2 OEC FLUOROSTAR screens + brightness amplifier (OEC 09TO) • A Sony UP-970AD hybrid graphic printer • Software version REV04.00.06 • Display versions: 4.00.58, BV: 4.00.33 • Installed options: Bitmap, Dicom Features : Generator • High frequency 20 kHz • 2.2 kW Monobloc • Up to 110 kVp • Up to 8 mA in fluoroscopic mode • Up to 20 mA for exposing radiographic films • High-performance pulsed mode up to 8 mA • Pulse width: 50 ms • Digital spotlight up to 8 mA X-ray tube • Fixed anode X-ray tube • Nominal focal points of 0.5 and 1.5 mm • Total filtration of the entire tube assembly > 3.9 mm Al Collimator Preview • Display of the collimator position on the screen • Iris PreView and dual-blade collimator • Independently adjustable asymmetric shutters • Adjustment of collimators without X-ray exposure Standard fluoroscopic mode • kVp range: 36-110 • mA range: 0.2-3 • Automatic and manual fluoroscopic modes Fluoroscopic hip mode • kVp range: 36-110 • mA range: 0.2-5.4 • Automatic and manual fluoroscopic modes Low-dose fluoroscopic mode • kVp range: 36-110 • mA range: 0.2-3 • Automatic and manual fluoroscopic modes Pulsed fluoroscopic mode • kVp range: 36-110 • mA range: 0.2-5.4 • Pulse frequency: 1, 2, 4, 8 Hz • Automatic and manual fluoroscopic modes Low-dose pulsed fluoroscopic mode • kVp range: 36-110 • mA range: 0.2-3 • Pulse frequency: 1, 2, 4, 8 Hz pps • Automatic and manual fluoroscopy modes High-performance pulse mode Fluorescent mode • kVp range: 36 to 110 • mA range: up to 8 • Pulse rate: 1, 2, 4, 8 ips • Automatic and manual fluoro modes • Pulse duration: 50 ms Digital spot mode • kVp range: 36 to 110 • 8 mA • Automatic exposure stop • Automatic image recording Radiographic mode • mA range: 20 • mAs range: up to 80 • Exposure time: 0.1 to 4 seconds • Computer-controlled exposure time • Cassette holder: 25.4 cm x 30.5 cm Video Imaging System Precision imaging features • Automatic window: Automatically adjusts brightness and contrast to produce a high-quality image. • Automatic control of exposure rate • Average filter • Edge enhancement filter • Predefined imaging profiles: standard, dense anatomy (hip), hand, thorax, reduced dose. 23 cm Image Intensifier • Tri-mode image intensifier tube 23 cm/15 cm/11 cm • Minimum central resolution (on monitor): - 9” (23 cm): 2.0 lp/mm - 6” (15 cm): 2.8 lp/mm - 4.5” (11 cm): 3.2 lp/mm • DQE: 65% (typical) • Grid: 8:1 ratio Video camera • High-resolution CCD camera 1000 × 1000 pixels • Fully digital interface • Fixed gain control Video display • 19” (48 cm) monochrome TFT-LCD flat screen - Tilt: 23 cm - Viewing angle: 160° horizontal and vertical • Minimum brightness: 800 cd/m² • Maximum brightness: 1000 cd/m² • Minimum contrast ratio: 800:1 • High resolution 1280 x 1024 • External video output: - DVI-I connector (compatible with VGA and DVI-D analog signals) - Fixed resolution of 1280 x 1024 pixels Image processing • 1K x 1K x 12-bit image processing • Dynamic recursive filter with motion adaptation - Allows the user to adjust the noise filter levels for optimal image quality - Guarantees optimal image quality even in case of movement • Automatic control of digital brightness and contrast • Manual control of digital brightness and contrast • Improved contours • Image negation mode • Automatic image recording and saving • Image exchange • Last image retention (LIH) • Zoom (up to 1600%) and image navigation • Left-right inversion • Up-down inversion • Digital image rotation - Real-time 360° rotation for dynamic and static images - Image positioning without additional exposure • Image annotation - Laterality (left/right) - Comments • Storage for 15,000 images Exam management • Patient information - List of exams - Personalized patient information • Display and summary of the DAP/X-ray dose • Export and print the DAP/X-ray dose summary • DICOM interface (optional) - Storage - Impression - Work list - Structured Radiation Dose Report (RDSR) - MPPS